scripts default iconCone beam CT simulation (Scripts) Publisher's description

Department of radiation oncology, school of medicine

Cone beam CT simulation

By: Deshan Yang, PhD
Department of radiation oncology, school of medicine, Washington University in Saint Louis
Email: dyang@radonc.wustl.edu

compute_projections.m - the main program, to compute all projection and save the 2D projection images into a folder
compute_one_projection.m - Called by the main program to compute only one projection image
straight_line_integral.m - The core function to compute a line integral through a 3D matrix
A lot of lines are commented out in this file because the file was originally written
in MATLAB only, and laterly rewritten into c for speed improvement.
straight_line_integral_inner.c - This is what rewritten in C from the straight_line_integral.m
sort_ts1_ts2.c - A utility function to combine two sorted array into one sorted array.
It is written in c to improve the speed

create_CSV_file_for_OSCaR.m - To create the CSV file which is used in OSCaR CBCT reconstruction
However, OSCaR does not support the saved mat data files without modification.
I have the modified OSCaR functions.

load_all_projection_images.m - Loading all projection images from a folder into a 3D volume
make_sure_positive.m - A small utility function

Binary files:
*.mexw32, *.mexw64 The compiled binary MEX files for 32-bit and 64-bit windows

Other files: - For different ways to compute projections. They are not in use anymore because
they are either much slower or less accurate

How to setup the 3D data:
You need to prepare an image 3D volume as the digital phantom (or patient, or object, whatever you call it).
For this main function: compute_projections(xs,ys,zs,data3d,mode,output_folder)
xs: the x coordinates of the image pixels in an array
ys: the y coordinates of the image pixels in an array
zs: the z coordinates of the image pixels in an array

xs, ys and zs should be centered at [0,0,0] which is the CBCT isocenter.

About computation performance:
The straight_line_integral function is partially written in c. It is very accurate and fairly fast.
The computation of projection implemented here is both faster and more accurate than the radon transformation code in MATLAB.
For a 3D matrix (512x512x176), it takes about 35 seconds to compute one 2D projection in resolution of 512x384 on a DELL with 2.33 GHz CPU.
Computation does not need a lot of RAM from my understanding.

System Requirements:

MATLAB 7.6 (R2008a)
Program Release Status: New Release
Program Install Support: Install and Uninstall

Cone beam CT simulation (Scripts) Tags:

Click on a tag to find related softwares

Is Cone beam CT simulation (Scripts) your software?

Manage your software

Most Popular

scripts default icon ASK, OOK, FSK, BPSK, QPSK, 8PSK modulation 1.1
ASK, OOK, FSK, BPSK, QPSK, 8PSK modulation contain several functions for digital modulation simulation
scripts default icon Simulink Communication Labs 1.1
Simulink Communication Labs allows you to learn communication systems in greater depth.
scripts default icon M-QAM modulation and demodulation 1.1
M-QAM modulation and demodulation is the QAM modulation and demodulation tech.
scripts default icon LZW Compression/Decompression 1.1
LZW Compression/Decompression - Updated LZW compressor and decompressor with reasonable performance
scripts default icon InSPIRE utility to plot a 2D displacement field (Scripts) 1.0
This program plots the deformation field (displace vectors) contained in vector.txt.